If there is more than one WMS pickface bin setup is set up for the same stock code in the same Warehouse, this module will take the lowest Min Minimum value and the highest Max Maximum value for the update and send it them to the SYSPRO InvWarehouse table.
Info |
---|
The data in the Datascope WMS tables is setup at a bin level, and the data in SYSPRO is held at a Warehouse level. Therefore, this module takes the Pickface bins and stock codes settings and update SYSPRO at a Warehouse level. |
This module is used to update the fields in SYSPRO, so that SYSPRO data can be included in reporting or planning within SYSPRO core software.
Select the appropriate pickface Warehouse by selecting the drop-down and select a Warehouse.
Select the Refresh icon to load the data grid
The data in the data grid will load and be displayed in red
Select the Update button
The data will be uploaded to SYSPROthe applicable pick face warehouse from the Warehouse field drop-down.
The data grid will load.
If the line is green, then SYSPRO has been updated; if the line is red, you must still do an update.
The screen will update the MinQty configured for the one pick face bin and the MaxQty from the other pick face bin if it is different, but both for the same stock code.
Select Update.
The SYSPRO warehouse will update.
All lines that post successfully to SYSPRO will turn green.
Page Tree Search | ||
---|---|---|
|
SPECIAL FEATURES
None
TECHNICAL
None The Pickface Query report can enables operators to quickly identify the designated pick face bin for a specific stock code within the system
TECHNICAL
A system setting change is required in order to allow adding one stock code to multiple pick face bins. Browse Settings / System Settings on the Ribbon Bar and locate the PICKFACE system name. Update the ALLOW_MULTI_PICKFACE_SETUP to Y(es). If N(o), the system will block the creation of multiple pick face bins for a single stock code.
SYSPRO REQUIREMENTS & Business objects used
None
REFERENCE
WHS022