Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Info

System Manager

DATASCOPE WMS SYSPRO Panels are Datascope DATASCOPE WMS screens visible within SYSPRO , but viewing DATASCOPE WMS data.

It is installed as part of the standard DATASCOPE WMS and is activated by the DATASCOPE WMS License file. Once the module has been activated within the license, the panels can be added to the SYSPRO Screen at a User/Role level as required.

These panels can be downloaded and installed from the through System Manager -. Please see the System Manager section for more details.

The installation of the DATASCOPE WMS SYSPRO Panels consists of two components, the Server Component, and the SYSPRO Client Component. These two components are described below in more detail.

Info

If you don’t like reading, you can watch the video.

Panel
panelIconId1f3a5
panelIcon:movie_camera:
panelIconText🎥
bgColor#DEEBFF

<no video>None

premium_SYSPRO_PANEL_INSTALLATION_CONFIGURATION_product_userguide_QG - v0.12.docxpdf

Try it!

Server Component Install

The DATASCOPE WMS SYSPRO Panels are relatively simple to install. In the latest version of DATASCOPE WMS, the panels are automatically installed as part of the WMS Installation. In the earlier version, before v 5.0.1, the The installation files can be downloaded via the System Manager / Download a Port/Upgrade section, as shown below:

Image Removed

Should you be on v5.0.1 or later, you can skip to the SYSPRO section below for further instructions on updating to the latest panels. For versions before v5.0.1, download the. MSI file as per the above image and proceed with the installation. This is a very simple “next,” “next,” “next” installation, with no options to choose from as follows:

     

Image RemovedImage RemovedImage RemovedImage Removedimage-20240611-092454.pngImage Added

Installing SYSPRO Panels

Ensure you have System Manager installed.

  • Open System Manager

  • Select 2. Download a Port/Upgrade

image-20240611-092849.pngImage Added
  • Select Next

  • Select Tools from the Download Filter drop-down. Then select one of the two SYSPRO Panel.msi files from the Download drop-down.

image-20240611-092856.pngImage Added
  • Select Next

  • The .msi file will download.

image-20240611-092911.pngImage Added
  • You can save the .msi file under your Downloads folder.

image-20240611-092917.pngImage Added
  • Select Next on the System Manager screen. You will be returned to the front page of the System Manager.

  • You can close System Manager

  • Open your Download folder from File Explorer and run the SYSPRO Panel .msi file. (double-click to run)

image-20240611-092935.pngImage Added
  • Select Next

image-20240611-092942.pngImage Added
  • Select Next

image-20240611-092948.pngImage Added
  • Select Next. The software will be installed.

  • Select Yes and the next screen.

image-20240611-092955.pngImage Added

Once the installation is complete, a new Windows Service will be located installed under Services, as shown below. This is the core service required for the panels to communicate with WMS and SYSPRO.

  • Once installed, you can close the Installation Complete screen.

  • To locate the Service, search for it from your Windows search.

Image Removedimage-20240611-093040.pngImage Added
  • Before starting the service, there is a single configuration file that needs to be updated; this is

located
  • in the following path:

C:\Program Files (x86)\DATASCOPE\DATASCOPE WMS SYSPRO Panels

image-20240611-093049.pngImage Added
  • The file is named as follows:

WMS.SysproExtensions.ServerService.exe.config

image-20240611-093055.pngImage Added
  • Open this file in Notepad

and edit
  • . Right-click on the file name and select Open with.

image-20240611-093102.pngImage Added
  • Edit the following lines to reflect the WMS Server IP/Name as shown below:

Image Removed
image-20240611-093107.pngImage Added
Info

Note: Ensure you have Edit / Write permissions for the folder.

  • Once this is done, the Windows Service mentioned above can be started, which completes the installation of the panels' Server Component

of the panels
  • .

image-20240611-093114.pngImage Added

WMS Client Components

Once the Server Component is installed, the SYSPRO Client Component must be copied over to the SYSPRO Server.

  • The files required are

located
  • in the Server Installation directory, as shown below:

C:\Program Files (x86)\DATASCOPE\DATASCOPE WMS SYSPRO Panels\SYSPRO Files

image-20240611-093527.pngImage Added
  • There are two files required, the DLL and the Configuration file, as shown below:

Image Removedimage-20240611-093533.pngImage Added
  • In

windows explorer
  • Windows Explorer, copy these files and copy them to the following location on the SYSPRO Server:

C:\SYSPRO7\Base\ManagedAssembliesIt should be noted that the

image-20240611-093539.pngImage Added
Info

Note: The “SYSPRO7” part of the above path depends on your specific installation of SYSPRO and may differ from this. However, the remainder of the path is consistent and should be followed.

  • Once the two files are copied, the WMS.SysproExtentions.Cloent.dll. config file should be edited to reflect the correct WMS Server IP/Name as shown below:

Image Removedimage-20240611-093547.pngImage Added
    Typically, the
    • The port can typically be left unchanged. This concludes the installation of the panels.

    Please follow the configuration section below for details on setting up the panels within SYSPRO.

    Activation in SYSPRO

    This section will detail the details of activating a Panel within SYSPRO.

    WMS Available Stock Panel

    This panel can be added to the SYSPRO Inventory Query and SYSPRO Sales Order Entry screens within SYSPRO as follows:

    • Select the drop-down list on an existing form and select Customized Pane->New, as shown below.

    • Specify a Name, .Net Control, and the DLL and Method as indicated below:

    • Click Save and “No” to the scripting question as shown below:

    • Link the Stock code and Warehouse fields to the new Panel by right-clicking and selecting the “Link to .Net Control” option.

    • This concludes the WMS Available Stock Query setup; the panel should now load information when the Stock code and Warehouse are selected, as shown below:

    Image RemovedImage Added

    The following panels are currently available:

    Child pages (Children Display)

    DATASCOPE WMS Picking Slips Panel

    This panel can be added to the Sales Order Entry screen within SYSPRO. The exact process as described above should be followed. In this case, the Links for this Panel are the Customer and Sales Order, as shown below:

    This panel will show any Picking Slips for the specific Customer and Sales order. This panel will also allow for Picking Slips to be released using the Picking Slip Release panel. This final Panel requires a VB script to be added to the Sales Order Entry Header. If the VB script is place implemented, the Release Panel will be displayed on the End Order button on the Sales Order Entry screen.

    DATASCOPE WMS Picking Slips Release Panel

    As mentioned above, this final panel depends on adding a VB Script as part of the WMS Picking Slips panel. Once the WMS Picking Slip panel has been added to the Sales Order Entry screen, click on the admin menu, and select System Settings, as shown below:

    This will display the following screen. Selecting the “VB Script Examples” button will display some sample VBScripting. Copy this script.

    The script should then be added to the Sales Order Entry Header, as shown below:

    Once this is added, the below Picking Slip Release panel will be displayed to the operator when the End Order button is pressed.

    The operator can then review the WMS Reservations and Release a Picking Slip, close the screen, etc.