Info |
---|
System Manager |
DATASCOPE WMS SYSPRO Panels are Datascope DATASCOPE WMS screens visible within SYSPRO , but viewing DATASCOPE WMS data.
It is installed as part of the standard DATASCOPE WMS and is activated by the DATASCOPE WMS License file. Once the module has been activated within the license, the panels can be added to the SYSPRO Screen at a User/Role level as required.
These panels can be downloaded and installed from the through System Manager -. Please see the System Manager section for more details.
The installation of the DATASCOPE WMS SYSPRO Panels consists of two components, the Server Component, and the SYSPRO Client Component. These two components are described below in more detail.
Info |
---|
If you don’t like reading, you can watch the video. |
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
<no video>None premium_SYSPRO_PANEL_INSTALLATION_CONFIGURATION_product_userguide_QG - v0.12.docxpdf |
Try it!
Server Component Install
The DATASCOPE WMS SYSPRO Panels are relatively simple to install. In the latest version of DATASCOPE WMS, the panels are automatically installed as part of the WMS Installation. In the earlier version, before v 5.0.1, the The installation files can be downloaded via the System Manager / Download a Port/Upgrade section, as shown below:
Installing SYSPRO Panels
Should you be on v5.0.1 or later, you can skip to the SYSPRO section below for further instructions on updating to the latest panels. For versions before v5.0.1, download the. MSI file as per the above image and proceed with the installation. This is a very simple “next,” “next,” “next” installation, with no options to choose from as follows:
Ensure you have System Manager installed.
Open System Manager
Select 2. Download a Port/Upgrade
Select Next
Select Tools from the Download Filter drop-down. Then select one of the two SYSPRO Panel.msi files from the Download drop-down.
Select Next
The .msi file will download.
You can save the .msi file under your Downloads folder.
Select Next on the System Manager screen. You will be returned to the front page of the System Manager.
You can close System Manager
Open your Download folder from File Explorer and run the SYSPRO Panel .msi file. (double-click to run)
Select Next
Select Next
Select Next. The software will be installed.
Select Yes and the next screen.
Once the installation is complete, a new Windows Service will be located installed under Services, as shown below. This is the core service required for the panels to communicate with WMS and SYSPRO.
.
Once installed, you can close the Installation Complete screen.
To locate the Service, search for it from your Windows search.
Before starting the service, there is a single configuration file that needs to be updated; this is
in the following path:
C:\Program Files (x86)\DATASCOPE\DATASCOPE WMS SYSPRO Panels
The file is named as follows:
WMS.SysproExtensions.ServerService.exe.config
Open this file in Notepad
. Right-click on the file name and select Open with.
Edit the following lines to reflect the WMS Server IP/Name as shown below:
Info |
---|
Note: Ensure you have Edit / Write permissions for the folder. |
Once this is done, the Windows Service mentioned above can be started, which completes the installation of the panels' Server Component
.
WMS Client Components
Once the Server Component is installed, the SYSPRO Client Component must be copied over to the SYSPRO Server.
The files required are
in the Server Installation directory, as shown below:
C:\Program Files (x86)\DATASCOPE\DATASCOPE WMS SYSPRO Panels\SYSPRO Files
There are two files required, the DLL and the Configuration file, as shown below:
In
Windows Explorer, copy these files and copy them to the following location on the SYSPRO Server:
C:\SYSPRO7\Base\ManagedAssembliesIt should be noted that the
Info |
---|
Note: The “SYSPRO7” part of the above path depends on your specific installation of SYSPRO and may differ from this. However, the remainder of the path is consistent and should be followed. |
Once the two files are copied, the WMS.SysproExtentions.Cloent.dll. config file should be edited to reflect the correct WMS Server IP/Name as shown below:
The port can typically be left unchanged. This concludes the installation of the panels.
Please follow the configuration section below for details on setting up the panels within SYSPRO.
Activation in SYSPRO
This section will detail the details of activating a Panel within SYSPRO.
WMS Available Stock Panel
This panel can be added to the SYSPRO Inventory Query and SYSPRO Sales Order Entry screens within SYSPRO as follows:
Select the drop-down list on an existing form and select Customized Pane->New, as shown below.
Specify a Name, .Net Control, and the DLL and Method as indicated below:
Click Save and “No” to the scripting question as shown below:
Link the Stock code and Warehouse fields to the new Panel by right-clicking and selecting the “Link to .Net Control” option.
This concludes the WMS Available Stock Query setup; the panel should now load information when the Stock code and Warehouse are selected, as shown below:
The following panels are currently available:
Child pages (Children Display) |
---|