Tab Settings on scanners

None

Use this guide to learn how to adjust the Auto Tab setting on scanners.

All our scanner applications are designed on HTML5 and run on Android version 8 or later. Therefore, the software can run on any external Android device, however we’ve identified a few preferred devices. For more information on these devices refer to our website - https://datascopewms.atlassian.net/wiki/spaces/UG/pages/226918403

By design, if you press Enter you activate a button (for example the Post button) to go to a next screen or action, however, some of our HTML 5 scanner applications have multiple fields and therefore you cannot Enter from one field to the next but must rather use TAB to go from one field to the next.

This user guide explains the settings to be changed for the following devices, so that you can Tab from one field to the next and not use the Enter key.

DATALOGIC Scorpio X5

Honeywell CK65

Chainway C61

If you don’t like reading, you can watch the video.

Try it!

DATALOGIC Scorpio X5

The following process explain how to set the Auto TAB functionality on a DATALOGIC Scorpio X5 scanner when scanning barcodes.

  • On your scanner screen you can drag up from the little Options button upwards

image-20240307-114021.png
  • Various options will be available, select the Settings option

image-20240307-114027.png
  • Locate the DataLogic Settings section

  • Browse to the Scanner Settings

  • From the Scanner Settings screen you can select Formatting

  • Select Standard Formatting

  • Select the Label Suffix option

  • Select the drop-down option next to Add Special and select [HT]. [HT] refer to the Tab character on the scanner

  • Select OK

  • Next, you must use your back button twice to go back two screens. Ensure to stop on the Scanner Settings screen

  • Scroll down to Commit and select

  • A Commit pop-up will appear. Select OK

  • You have now changed the Auto Tab functionality to TAB between fields on the same screen and not Enter.

Honeywell CK65

The following process explain how to set the Auto TAB functionality on a Honeywell CK65 scanner when scanning barcodes.

  • On your scanner screen you can drag up from the little Options button upwards

  • Various options will be available, select the Honeywell Settings option

  • Browse to Scanning

  • Select the Internal Scanner option

  • Select Default Profile setting

  • Select the Data Processing setting

  • Open the Suffix setting

  • Enter the value \t and select OK (this is the Auto Tab option)

  • You have now changed the Auto Tab functionality to TAB between fields on the same screen and not Enter

Chainway C61

The following process explain how to set the Auto TAB functionality on a DATALOGIC Scorpio X5 scanner when scanning barcodes.

  • On your scanner screen you can drag up from the little Options button upwards

  • Various options will be available, located the KeyboardEmulator app as indicated below

  • Once opened, select AppSettings and scroll down to the End mark option. Ensure ONLY the TAB option is selected, and not the Enter option