Link Purchase Order to COA [REC002]

A COA (Certificate of Analysis) must be linked to a received product’s batch (LOT) number. This is specifically required in the chemical, food, and pharmaceutical industries. These COAs are usually required when a product is sold to a client or is used as a reference for quality control.

  • Start by entering a From and To Receipt Date OR enter a GRN number

  • Select or deselect the Only Show When COA Number is ‘NONE’

If Only Show When COA Number is ‘NONE’ is not selected, it will display the lines where a COA is already linked.

  • Select the Refresh icon to load the data grid.

  • The screen will display all Purchase Orders where a COA is required and the COA number is equal to NONE

All Purchase Orders that require a COA number
  • Select a line on the grid, the blue fields for stock codes, the PO number will populate

  • Enter a COA number in the Link to COA field and select the Link button.

  • Once the COA has been linked the line will disappear from the data grid.

SPECIAL FEATURES

  • The user must first enter a COA number during the PO Receipt process. If the number is not available, the user must enter NONE. A Custom Form field must be created for this in SYSPRO

TECHNICAL

  • To link the COA Custom Form Field created in SYSPRO with DATASCOPE WMS, a System Setting must be updated. From the Ribbon bar, select Settings / System Settings and locate RECEIVING in the System Name drop-down. Update the COA_REQUIRED_FIELD value to the Field name within the SYSPRO Custom Form Field. Example: COA001

  • To record a COA number, a System Setting must be updated. Select Settings / System Settings from the Ribbon bar and locate RECEIVING in the System Name drop-down. Update the COA_ACCEPTED_FIELD value to Y(es).

SYSPRO REQUIREMENTS & Business objects used

  •  A GRN number is generated within SYSPRO and then passed to WMS.

REFERENCE

REC002